Hotpoint WM72 Error Code E30

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hotpoint WM72 Error Code E30

Viewing 8 posts - 1 through 8 (of 8 total)
  • Author
    Posts
  • #6935
    Taff
    Participant

    Went to this machine, with error code E30. Checked filter which was blocked. Checked brushes which were worn, changed these. Selected rinse and spin program, machine filled but as soon as the motor should have turned Error E30 displayed. Selected spin, machine drained but when motor rotation should have occured again E30 displayed. Changed motor same fault. No visible burn marks on PCB the one where the motor loom clips on. Any ideas??

    Regards
    Taff

    #120471
    Penguin45
    Participant

    Motor cicuit potection fuse? Dodgy wiring in motor connector block? Triac?

    Chris.

    #120472
    Taff
    Participant

    Re: Hotpoint WM72 Error Code E30

    Where is the fuse located. Appreciate the reply.

    Regards

    Taff

    #120473
    Martin
    Participant

    Re: Hotpoint WM72 Error Code E30

    Taff wrote:Where is the fuse located. Appreciate the reply.

    Taff,

    Don’t think it has one actually 😕

    I suspect as in most cases the motor fault* has blown the triac in the Power module (1603283) especially if it is the earlier version with the big transformer soldered on 😉

    Martin

    * If the insulation reading of the old armature goes higher than 4 or 5 megohms it will blow the board (not visibly though)

    #120474
    lokring
    Participant

    Re: Hotpoint WM72 Error Code E30

    i know this sounds stupid! this fault will be the heater i know it dosent seem possible but try it before you go buying pcbs

    #120475
    AMS
    Participant

    Re: Hotpoint WM72 Error Code E30

    What about the thermal cut-out in the motor? Do a continuity check through the brushes/armature from the the motor socket. If open circuit then it’s gone.

    #120476
    Taff
    Participant

    Re: Hotpoint WM72 Error Code E30

    Changed Circuit Board problem solved. Thanks to all who offered advice.

    Regards Taff

    #120477
    Martin
    Participant

    Re: Hotpoint WM72 Error Code E30

    Taff wrote:Changed Circuit Board problem solved.

    Thought as much, nice one Taff 😀

    Martin

Viewing 8 posts - 1 through 8 (of 8 total)