    rocker
    Participant

    This machine aborts stright after start up …tested heater for earth leaks ..sent pcb to EMW (no fault found)
    can anyone offer any advice. please John

    #374816
    SL
    Participant

    Re: Zanussi ZWF12070W

    Change the motor, well known problem

    #374817
    clockworkone
    Participant

    Re: Zanussi ZWF12070W

    usually triac gone on board caused by inlet valve or interlock ,but as you have had board checked motor or wiring fault.whats coming up on diagnostics.

    #374818
    rocker
    Participant

    Re: Zanussi ZWF12070W

    not sure how to set up diagnostics. any advice please.
    john

    #374819
    Martin
    Participant

    Re: Zanussi ZWF12070W

    rocker wrote:not sure how to set up diagnostics. any advice please.

    It’s the usual :

    1. Switch off the appliance.
    2. Press and hold down START/PAUSE button and the nearest option
    button.
    3. Holding down both buttons, switch the appliance on by turning the
    programme selector by one position clockwise.
    4. Continue to hold down the button till the LEDs begin to flash (at least 2
    seconds).
    In the first position, the operation of the buttons and the relative LEDs is
    checked; turning the selector knob clockwise the diagnostics cycle for the
    operation of the various components and the alarm reading is activated.

    The rotate dial to position 10 to read the error code. 😉

    #374820
    clockworkone
    Participant

    Re: Zanussi ZWF12070W

    pm your email add.paul

    #374821
    rocker
    Participant

    Re: Zanussi ZWF12070W

    Thanks for info Martin.
    Paul, have pm you my email.
    John

    #374822
    clockworkone
    Participant

    Re: Zanussi ZWF12070W

    sent.paul