    raw
    Blocked

    siemens dryer WT66080GB/02
    put it on extra dry, time in window display starts at 137, 136,135 then goes to zero and dryer stops wont do anything,is this gonna be board fault

    #376693
    nomadPaul
    Participant

    Re: Siemens dryer

    Are you testing it with a wet load in it ? if yes , then I’d be checking the temp limiter first. if no , try it loaded ! unlikely to be a board fault .

    #376694
    raw
    Blocked

    Re: Siemens dryer

    it was tested empty

    #376695
    nomadPaul
    Participant

    Re: Siemens dryer

    Its a sensor dryer so no load = no operation after 2/3 mins . It needs a wet load in it to test properly and then see what indications it gives if it fails then.