    Hi all, I changed the evap cover [da9705290q] and sensor [da300006w] on this f/f for noisy fan problen as everything else metered out ok but the noise returned ,I went back and checked it out again and heaters and fuse ok . Am I missing something ❓
    Would anyone have a service manual for this machine.
    Thinks Mark.

    #377267
    A1engineer
    Participant

    Re: samsung Rs21dcns

    pm me your email ill send you some light reading 🙂

    #377268
    MDE
    Participant

    Re: samsung Rs21dcns

    Thank A1, one more thing, the evap cover I got from Connect was not a direct replacement, I had to take the connectors of the old one to make it fit, but it was the right part number, anyone got any thoughts on that ?

    #377269
    funkyboogy
    Participant

    Re: samsung Rs21dcns

    wire old of fan should be ok . seen this a few times as long as you swap from old fan to new it works ok ..

    one thing to check is – has the customer had the fuse kit fitted , if so the fuse can blow if the defrost heater has went o/c

    so thus you put new parts in but it wont go onto defrost..

    best way to check is put onto test mode and check for 240 at defrost heater terminal .. if no 240 then fuse probaly o/c

    or you could just take out pcb and check fuse ..