    Good Evening All.

    I went to this washer dryer today, dryer not heating. Manual reset (r/h) had popped. I measured the thermistor at approx 50kohm. Is this a bit on the high side?. Anyone know what normal at ambient is on these?.

    All responses greatly appreciated.

    Regards,

    mike

    #377742
    BobHope
    Participant

    Re: Candy CMD146-80 washer Dryer

    at 25c it should read 48.5k. have you changed the manual resets to the 185c type as the old ones were 175c.

    Bob.

    #377743
    mike412
    Participant

    Re: Candy CMD146-80 washer Dryer

    Hi Bob, Thanks for your prompt response.

    Looks like the NTC is about right as it was a hot day when I last went.

    I changed the pair of stats 2-3 months ago but I cant recall what the temps were. If you have the part number for the 185deg handy that would be useful, if not I will put in a part enquiry with CDSL.

    Many Thanks, Mike.