Whirlpool D/W F06?

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #70536
    iadom
    Moderator

    12nc:851144015870

    Water supply OK, fill valve OK.

    Set to any programme and machine drains then stops dead, after a few seconds beeps and flashes 6 times.

    Doesn’t have the doofer in the sump that usually gets gunged up, possibly flow meter/impellor but when these go it usually does try to fill for a short while, not had one totally dead due to flow meter.

    Is that the most likely suspect, if so does anyone have the part number of the flow meter/fill chamber?

    TIA.

    Jim.

    #378333
    Galway
    Participant

    Re: Whirlpool D/W F06?

    check that reed switch is sitting in right position and that connections are good.if reed switch is visable on this model then if can easily be replaced.
    Niall

    #378334
    iadom
    Moderator

    Re: Whirlpool D/W F06?

    Can you confirm that a faulty reed switch would give no fill at all, all the ones I have seen do at least attempt to fill for a second or so?

    #378335
    Galway
    Participant

    Re: Whirlpool D/W F06?

    no cant confirm that but they are cheap so might be worth a go.
    is the fill valve getting 230v? even for a split sec.
    what type of pressure switch is in the sump.is it the usual mesh front or the newer pressostat?

    #378336
    iadom
    Moderator

    Re: Whirlpool D/W F06?

    Doesn’t have the old type pressure switch in the sump. Just had a look in my garage and have a complete fill chamber assy, do you know if 481241868147 will fit this particular machine?

    Jim.

    #378337
    iadom
    Moderator

    Re: Whirlpool D/W F06?

    Sorted, broken wire in door harness. 8)

    Jim.

    #378338
    Galway
    Participant

    Re: Whirlpool D/W F06?

    sorry Jim
    i was away all weekend .
    good to see you got it sorted 😀

Viewing 7 posts - 1 through 7 (of 7 total)