Miele G1220SC Blows fuse 15mins into cycle?

Home Forums Public Support Forums Help And Support Dishwasher Help Forum Miele G1220SC Blows fuse 15mins into cycle?

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #70728
    classicfordandy
    Participant

    Hi all thanks for any help in advance, I have a G1220SC that blows the fuse in the plug after 10-15mins into cycle I think I’ve seen F14 displayed but not 100{e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d} sure could this be linked? I have 29 ohms across the heater and have checked the main board out and am now stuck…
    Thanks again for any replys.

    #378809
    Seamy
    Participant

    Re: Miele G1220SC Blows fuse 15mins into cycle?

    F14 is heater level switch fault. Most likely its the circulation pump motor not putting up enough pressure, likely theres something stuck in the impellor. Check wiring, especially to & from heating relay & check reading of heater to earth.

    #378810
    classicfordandy
    Participant

    Re: Miele G1220SC Blows fuse 15mins into cycle?

    Hi and thanks for your reply I have checked it out and now it runs without tripping. Set it to quick wash and it heats fine but when it gets to 14 mins left it pumps out and it sounds like an inlet solenoid is humming for 2 mins and just sits there till 1 min left pump comes on and off then end light comes on???? Ah help please.