Hotpoint EW81 – Tripping RCD When Hot

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hotpoint EW81 – Tripping RCD When Hot

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #70762
    Hollytree_Technical
    Participant

    Hi all

    This one is beginning to annoy me as I haven’t managed to find the cause yet but the situation is this:

    When cold the cooker has an insulation reading of approx 28M Ohm with no individual part below 6M Ohm, however when the oven has been on for 10 minutes the reading drops to 0.2M Ohm – I have rechecked all the elements and motors when hot and they don’t change in reading, I have also tried disconnecting the thermostat and selector switch but it doesn’t appear to make any difference either, I have even tried moving the wires and can’t get a change – What might I be missing? Has anyone had one like this before and what did it turn out to be as I am out of ideas.

    Thank you

    Jem

    #378874
    bazza500
    Participant

    Re: Hotpoint EW81 – Tripping RCD When Hot

    It will be the element.

    #378875
    Firestarter
    Participant

    Re: Hotpoint EW81 – Tripping RCD When Hot

    Door switch?

    #378876
    Hollytree_Technical
    Participant

    Re: Hotpoint EW81 – Tripping RCD When Hot

    Turned out that Bazza was right and that it was the element although I am sure that I metered the element at least twice when it was hot without the fault showing, also turned out that this one is a hybrid of the two wiring variations shown in the service manual.

    Jem

Viewing 4 posts - 1 through 4 (of 4 total)