Whirlpool AWG349/3 Washer Dryer

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Whirlpool AWG349/3 Washer Dryer

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #70926
    mike412
    Participant

    I am hoping someone can assist on this one.

    Its in a tenanted property and the tenant is complaining about smells from the tub.

    I have been down the “Service Wash” route but we are back to square 1.

    I am beginning to suspect that the Thermistor may have changed value and the machine is not heating to 90deg to achieve the sterilisation effect. I would like to test the thermistor but I dont have any information on what normal at ambient is.

    I would be most grateful if someone could assist with this information.

    Regards,

    Mike.

    #379379

    Re: Whirlpool AWG349/3 Washer Dryer

    You must be desperate if you’re having to grasp at such a straw. Not sure how modern your model is but I’d have thought it would give an error code if the ntc went wildly out. What else have you tried? I’d be looking at the drainage arrangement to see if dirty water is syphoning back from the sink waste for example.
    Mike.