Re: bosch SMV53M00GB/16
Well the pump operates on DC voltage. Resistance measurements between terminals should be 82 ohms (give or take 8 ohms) I.e term 1 to term 2 = 82 ohms 2 to 3 = 82 1 to 3 = 82 if you catch my drift?
The pump is fed directly by the module that detects any resistance fluctuations. Once it does it assumes the pump is blocked and attempts to clear the blockage by turning the power to it on and off. If, after a short time it fails to detect a normal resistance reading it stops altogether and flags up an E23, E24 or E25 error ( usually E23 as a rule though).
E25 is often accompanied by the ‘check tap’ symbol by the way and could just mean that the pump cover isn’t in position. So worth checking that first I reckon. 😉