Electra 17051

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #72460
    twicknix
    Participant

    This machine was DOA, stopped mid cycle.

    Manually drained the machine and released the door catch. Insulation test showed up as infinity. So I was unable to pinpoint what was the culprit.

    TBH I am not familiar with “manual” washing machine. It looks like it got an hybrid timer and I do not know how to test it. For some reason I think it was the timer as it would not power up.

    Yes I did check the capacitor and it works (closed circuits on both ends) and there is power going to the timer but nothing beyond that.

    Any ideas?

    #384579
    HotDog
    Participant

    Re: Electra 17051

    did you check door micro switch prone to wires burning off next take the connector block off the timer the one nearest to the front also prone to burning

Viewing 2 posts - 1 through 2 (of 2 total)