  • #72793
    AMS
    Participant

    This machine displays no signs of life at all. Got power to the main module. Is this a straightforward module change or am I missing something? Is this a common fault on these machines? Do the modules come pre-programmed?
    Cheers all,

    Dave

    #385554
    iadom
    Moderator

    Re: Hotpoint TCL780 tumble dryer

    main neutral feed is through the toc stat AFAIK,

    #385555
    AMS
    Participant

    Re: Hotpoint TCL780 tumble dryer

    Would that be on the element or the front one Jim?

    #385556
    iadom
    Moderator

    Re: Hotpoint TCL780 tumble dryer

    There is only one toc, it’s above the element .

    #385557
    AMS
    Participant

    Re: Hotpoint TCL780 tumble dryer

    Thanks Jim, I’ll check it out tomorrow.

    #385558
    madangler1
    Participant

    Re: Hotpoint TCL780 tumble dryer

    Catches a few out this. As above go with the one shot.

    Replace and fin the cause of failure. Air flow blockage, filters, motor capacitor.

    #385559
    johnnyj
    Participant

    Re: Hotpoint TCL780 tumble dryer

    Did you check the stats the A1 module if the one shot is blown you get no power, A2 module it will work but no heat cheers JJ

    #385560
    AMS
    Participant

    Re: Hotpoint TCL780 tumble dryer

    Okay then, one-shot and cycling stat both good. Got continuity L and N all the way from plug to board. Any more suggestions?
    Thanks for all the replies so far btw.

    #385561
    iadom
    Moderator

    Re: Hotpoint TCL780 tumble dryer

    Full serial number and commercial code would help. 😉

    #385562
    AMS
    Participant

    Re: Hotpoint TCL780 tumble dryer

    Industrial code: 95686770000
    Serial no: 102034026

    #385563
    iadom
    Moderator

    Re: Hotpoint TCL780 tumble dryer

    Yours should have the later A2 module, neutral is not routed through the toc.

    PM me an e-mail address and I will send you some info.

    Jim.