Hotpoint Aquarius WF541 Temperature Control

Home Forums Public Support Forums Help And Support Washing Machine Help Forum Hotpoint Aquarius WF541 Temperature Control

Viewing 15 posts - 1 through 15 (of 15 total)
  • Author
    Posts
  • #72833
    desmarbilsam
    Participant

    I have a Hotpoint Aquarius WF541 which has worked perfectly for as long as I’ve had it. However, it has recently developed a fault on temperature control. It doesn’t matter which temperature setting I now select, it always washes everything, on any chosen wash cycle, at the highest possible temperature setting (ie everything washed at 95 degrees!!). Would this be caused by a faulty thermistor or would the temperature control switch be at fault?

    #385696
    iadom
    Moderator

    Re: Hotpoint Aquarius WF541 Temperature Control

    Its more likely to be the selector switch than the thermistor TBH.

    The selector switch is part of the console pcb which is around £100.00
    The thermistor does not appear to be available on its own, it comes with a new heater which is approx £24.

    #385697
    desmarbilsam
    Participant

    Re: Hotpoint Aquarius WF541 Temperature Control

    Thanks IADOM. Most helpful. Is the control switch on the Control PCB replaceable or would I need to purchase the whole PCB?

    #385698
    iadom
    Moderator

    Re: Hotpoint Aquarius WF541 Temperature Control

    It is a complete unit. Plug and pray, no programming needed.

    #385699
    madangler1
    Participant

    Re: Hotpoint Aquarius WF541 Temperature Control

    Unlikely to be selector if no matter the program it’s washing at 95, the temperature control can only reduce the temp of a given program it can not increase it, so if you select 40 cotton wash and its still washes at 95 then its more likely module. However if you are selecting the 95 cotton and can’t reduce it then id agree its the top board.

    #385700
    iadom
    Moderator

    Re: Hotpoint Aquarius WF541 Temperature Control

    Either way, it’s expensive or very expensive. 😥

    #385701
    madangler1
    Participant

    Re: Hotpoint Aquarius WF541 Temperature Control

    iadom wrote:Either way, it’s expensive or very expensive. 😥

    Lol.

    #385702
    desmarbilsam
    Participant

    Re: Hotpoint Aquarius WF541 Temperature Control

    Thanks very much for this advise. Just 1 question about your reply. When you refer to the “Module”, are you referring to the main PCB at the back of the machine? It sounds like an expense I could well do without on the run up to xmas 🙁

    #385703
    iadom
    Moderator

    Re: Hotpoint Aquarius WF541 Temperature Control

    The console or facia module is at the top and contains the rotary switches, cost around £100.

    The main module is in the base, cost over £100 but has to be programmed, either by an Indesit Company engineer or by purchasing a ‘one use only’ smart card (approx £20) and a card reader (about £100). 😥

    One of many reasons why lots of people insert the letter H between the S & I in Indesit. :rolls:

    #385704
    desmarbilsam
    Participant

    Re: Hotpoint Aquarius WF541 Temperature Control

    lol 🙂 Thanks for the advise. Much appreciated

    #385705
    helo_75
    Participant

    Re: Hotpoint Aquarius WF541 Temperature Control

    just a quick one

    has no one considered the knob might be broken?

    i mean, if the thermistor was faulty either way, there would be a fault code, amd if the relay was stuck on, same thing… but then , this is hotpoint isnt it

    #385706
    iadom
    Moderator

    Re: Hotpoint Aquarius WF541 Temperature Control

    Not seen the knobs on the small rotary switches breaking on these, but as you say Rob it is a Hotpoint (Indesit) so anything is possible. However as madangler1 has pointed out the temp switch cannot increase temps, only decrease them so if the knob was stuck in the 95 degree position and the machine was set to a 40 degree wash it should still only heat to 40.

    #385707
    Allsorts
    Participant

    Re: Hotpoint Aquarius WF541 Temperature Control

    I did have one of these the other day that was stuck on one program which was a 60 deg..

    Are you able to select other programmes ie. spin or drain. ??

    #385708
    desmarbilsam
    Participant

    Re: Hotpoint Aquarius WF541 Temperature Control

    Hi Allsorts
    I’ve checked the control knob and it appears to be fine. Turns and clicks as normal. Even removed the switch itself from the board to check it and it appears fine (no broken contacts). Cleaned all the contacts on the pcb in case there wsh a dirty connection and put the machine through a cycle again to see if it made a difference. Now it is doing all sorts of weird and wonderful things!!!! I put it on a drain cycle and it filled with water and did a complete wash cycle. Tried to end the cycle by pressing and holding the cancel button. All lights lit and then stopped …. momenterily before continuing on it’s wash cycle. Even turned it off using the on/off switch and about 4 seconds later..the machine turned itself back on and continued with the wash cycle. It’s now as though it has a mind of it’s own and it does it’s own thing!!!!!!

    #385709
    madangler1
    Participant

    Re: Hotpoint Aquarius WF541 Temperature Control

    Unfortunately I’d say you have killed to the top board. Regardless of the original fault now its done this after you “cleaned” it most likely needs a new one


    Save your self time and money and call an expert.

Viewing 15 posts - 1 through 15 (of 15 total)
  • You must be logged in to reply to this topic.