Beko drcs68w

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #72927
    franz
    Participant

    This t/d shuts down after about 10 mins – all lights out- dead, then will restart after about 15 mins – seems like an o/heat stat resetting . Is this like the hotpoint t/dryers where the supply goes through the stats and if they fail nothing works or is there a component on the pcb intermittantly failing? Any ideas appreciated.
    Franz

    #385976
    rub
    Participant

    Re: Beko drcs68w

    most likely the pcb however dont rule out the socket/plug, if you have a poor connection in the wall socket it can cause overheating in the plug. Does the plug get hot in use? it shouldnt. if not probably the pcb.

    Rub

    #385977
    franz
    Participant

    Re: Beko drcs68w

    Thanks Rub

    #385978
    franz
    Participant

    Re: Beko drcs68w

    have tried a pcb and front ntc – still cuts out after 10mins – all lights out and dead. anyone got any ideas or tech info.
    Thanks Franz

    #385979
    chitts
    Participant

    Re: Beko drcs68w

    Did you ever find the answer to this? I’ve been to one doing exactly the same. Everything seems clean and clear and fault occurs on timed or sensor cycles. Any clues please.

    #385980
    franz
    Participant

    Re: Beko drcs68w

    Cut off the moulded plug and replaced – must have been heating up inside – worked ok since
    Franz

Viewing 6 posts - 1 through 6 (of 6 total)