JLWD1609 timer problem Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › JLWD1609 timer problem This topic has 2 replies, 2 voices, and was last updated 13 years, 3 months ago by mic. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts December 18, 2012 at 9:47 am #73128 micParticipant Hi Looking at a JLWD1609 it shows no error code but the timer counts down twice as fast as it should and there is no neutral to the dryer heater. The thermostat and TOC are ok, the thermistor is 7.7k when cold. Any ideas? Thanks Michael December 18, 2012 at 6:41 pm #386510 SeamyParticipant Re: JLWD1609 timer problem The dryer element gets supply from J5-1 through t.o.c, & J8-3, J8-4, through relay 3 & 4 on p.c.b December 19, 2012 at 7:51 am #386511 micParticipant Re: JLWD1609 timer problem Thanks would the neutral supply being missing account for the timer issue Michael Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In