neff t/d

Viewing 8 posts - 1 through 8 (of 8 total)
  • Author
    Posts
  • #7340
    machineman
    Participant

    enr r4381x1gb/01 fd 8305 strange one this runs for about 3 or 4 mins then timer goes straight to 0 checked overheat stat. there is only the thermister that i could see besides that big module anybody seen one of these.m

    #122768
    superfix
    Participant

    Re: neff t/d

    Just a thought but is the condenser clear?.

    Sometimes get a blockage in the tube where it attaches to the condensed water drawer.

    Are there any lights flashing?

    #122769
    machineman
    Participant

    condenser pretty grotty/ cleaned still the same no lights flashing.m

    #122770
    Dave_Conway
    Participant

    Re: neff t/d

    Bleedin’ hell !!

    That’s a piece of kit, a fully integrated, condensing, sensor controlled tumble dryer, and it’s over £800 😯

    I’d go along with boro on that one, blokages in the pipe between the pump and water tray are the most common fault.

    Apart from that :con:

    Dave.

    #122771
    machineman
    Participant

    but why would it lock out and why did she move to Wales is this under g/tee to Boro.m

    #122772
    superfix
    Participant

    Re: neff t/d

    Yup it’s under g/tee alright.

    How do you mean lock out?

    #122773
    Dave_Conway
    Participant

    machineman wrote:but why would it lock out

    The water collection chamber is full, float switch (I think) activates and tells the PCB to shut down before it floods the place.

    What has her moving to Wales got to do with it ? 😆

    Dave.

    #122774
    superfix
    Participant

    Re: neff t/d

    Yeah float makes but machine still runs.

    Just cuts power to heater,so no more steam condenses.

    The “empty container” will light and alarm will sound after 2 minutes of

    float making.

Viewing 8 posts - 1 through 8 (of 8 total)
  • You must be logged in to reply to this topic.