american style side by side.serial number 1010027401.
I found evaporator fan,220v, open circuited and it smelt burnt out. there is no voltage at the fan socket so suspect that the fan has damaged the control pcb mounted in the door.the compressor is running fine. can anyone confirm that fan runs when compressor is running as there is no visible fan klixon.
Anyone had this problem before and who best to obtain spare from?
or with an open circuited motor.
i found Beko’s phone number and after a long wait they were very helpful.They offered me a 10{e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d} discount. parts ordered.
thanks for that. I know that on the maytag/ amana there is a klixon which only turns the fan on when the evap reaches -20. This beko didn’t have one so i guessed about the door being shut. Thanks again.