  • #73500
    kevinlewis
    Participant

    american style side by side.serial number 1010027401.
    I found evaporator fan,220v, open circuited and it smelt burnt out. there is no voltage at the fan socket so suspect that the fan has damaged the control pcb mounted in the door.the compressor is running fine. can anyone confirm that fan runs when compressor is running as there is no visible fan klixon.
    Anyone had this problem before and who best to obtain spare from?

    #387682
    Seamy
    Participant

    Re: BEKO FRIDGEFREEZER A190W

    It won’t run with door open.

    #387683
    kevinlewis
    Participant

    Re: BEKO FRIDGEFREEZER A190W

    or with an open circuited motor.
    i found Beko’s phone number and after a long wait they were very helpful.They offered me a 10{e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d} discount. parts ordered.

    #387684
    Seamy
    Participant

    Re: BEKO FRIDGEFREEZER A190W

    I mean if you are testing it for a supply with the door open you won’t get a supply at the fan connections with the door open.

    #387685
    kevinlewis
    Participant

    Re: BEKO FRIDGEFREEZER A190W

    thanks for that. I know that on the maytag/ amana there is a klixon which only turns the fan on when the evap reaches -20. This beko didn’t have one so i guessed about the door being shut. Thanks again.

    #387686
    kevinlewis
    Participant

    Re: BEKO FRIDGEFREEZER A190W

    it only required the fan. It took about 20 min before the sensor signaled the pcb to start it up.