Hotpoint Dryer TCD970 Help Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Hotpoint Dryer TCD970 Help This topic has 4 replies, 2 voices, and was last updated 13 years, 1 month ago by razor. Viewing 5 posts - 1 through 5 (of 5 total) Author Posts February 9, 2013 at 4:13 pm #74055 razorParticipant Hello all Just had customer call with fault with her dryer, fault code f07 anyone know as cant seem to find it anywhere online. many thanks February 9, 2013 at 4:34 pm #389765 iadomModerator Re: Hotpoint Dryer TCD970 Help Lower element failure. Check security of module connector J4; • Test between pins 4 and 3 on J4 (approximately 48 Ohms); • If open circuit, test lower element and wiring between J4 and the heater. February 10, 2013 at 10:30 am #389766 razorParticipant Re: Hotpoint Dryer TCD970 Help Many thanks iadom for quick reply would you happen to have the fault code list for these cheers Raymond February 10, 2013 at 11:23 am #389767 iadomModerator Re: Hotpoint Dryer TCD970 Help Yes, it’s HERE February 10, 2013 at 12:27 pm #389768 razorParticipant Re: Hotpoint Dryer TCD970 Help thanks iadom 🙂 Author Posts Viewing 5 posts - 1 through 5 (of 5 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In