Aeg Favorit 89020VI

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #74143
    franz
    Participant

    According to the customer the display shows I60. Any ideas what it means ?

    Thanks Franz

    #390151
    Martin
    Participant

    Re: Aeg Favorit 89020VI

    I60= Overheat problem, Element fault, NTC, Safety stats (open), low water circulation in tub too low, wash pump impellor fault or faulty PCB

    Any of the above…. All the best finding which. 😀

    #390152
    franz
    Participant

    Re: Aeg Favorit 89020VI

    Thanks Martin, I think
    Franz

    #390153
    TheSpinDoctor
    Participant

    Re: Aeg Favorit 89020VI

    You can test the continuity of the heater circuit usually from the PCB. It’s usually tag A2 to C5 & you are looking for 25-30 Ohms. If you get that, PCB is faulty.

    #390154
    franz
    Participant

    Re: Aeg Favorit 89020VI

    Thanks for that it will be a great help
    Franz

Viewing 5 posts - 1 through 5 (of 5 total)
  • You must be logged in to reply to this topic.