    I’ve just been to look at this on the assumption that the door lock needed replacement(site manager giving duff info!) only to find door lock ok but no matter what programme selected it just pumps forever, although the timer counts down. The flood protection is fine as are the main components as far as I can see. It’s a heavily used machine and my thoughts are pcb problem. Any clues?

    #391271
    Martin
    Participant

    Re: AEG L64840 Only pumps

    Insulation test clear was it?

    #391272
    chitts
    Participant

    Re: AEG L64840 Only pumps

    Yes, motor, heater ok.

    #391273
    Martin
    Participant

    Re: AEG L64840 Only pumps

    Then most likely the analogue pressure switch needs replacing I should think.

    #391274
    captaincaveman1
    Participant

    Re: AEG L64840 Only pumps

    Check sump and pressure bell arn’t clogged first