Hi all
Have this machine in for repair, customer complained that it was missing 20 and sometimes 30 mins from certain programmes.
Have this morning tried it on acottons 75 degreee wash.
Dsplay shows 1H 56M at start, it takes in water to fill sump
(Please note this model has the motorised valve at the back of the soap box, and only has the one inlet solenoid)
So you can hear the motorised valve operating to let water in through main wash compartment, machine then tumbles a few times, and then its at this point the timer drops 20 mins off..
I have noticed the water inlet is momentarily energised at this exact time.
If i knock the power off at front of machine, then put it back on, the normal time is then restored..
So my theorys are
1: dodgy inlet valve?
2: the heater is energised at about the same time, so could be that?
Have tried it on the automatic wash setting and seems to workmas it should.
any ideas most welcome..
Martin