Delongi dual range DFS 903-1

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Delongi dual range DFS 903-1

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #75640
    asp11
    Participant

    When the oven gets upto temp the clock display goes out, the appliance just stops all together but doesn’t blow the trip. After about 15/20mins the display comes back flashing so when it’s reset the machine starts up again ok.

    It sounds like a button style overload stat problem but why would it cut the clock display out and stop working?

    Any ideas welcome. Thanks

    #395714
    admin
    Keymaster

    Re: Delongi dual range DFS 903-1

    Overload temp toc cut out or wiring to it.Stops all power to unit so that it doesnt go on fire.

    Bryan

    #395715
    asp11
    Participant

    Re: Delongi dual range DFS 903-1

    Thankyou Bryan…. Where is this part situated reference access position to changing it. I’m not GasSafe registered so hope it’s available via the back panel – Do you know?

Viewing 3 posts - 1 through 3 (of 3 total)