h/pt bs1400

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #75742
    clockworkone
    Participant

    looking for fault codes for this w/machine. would be grateful for any tech on these also.paul

    #395993
    iadom
    Moderator

    Re: h/pt bs1400

    Same as general Indesit/Hotpoint codes.

    Fault Possible Causes & Actions
    F01 Motor piloting triac short circuit
    F02 Motor blocked / motor tacho open/short circuit
    F03 Wash NTC probe short/open circuit
    F04 ‘Empty’ + pressure switch overflow simultaneously
    F05 ‘Empty’ pressure switch not reached, drain pump
    clogged
    F07 No absorption of the wash heater
    F08 Wash heater relay welded to the NA/NC contact
    F09 Fault of set-up file (EEPROM not programmed or
    not working)
    F10 No signal of simultaneous ‘full’ and ’empty’
    F11 No supply to the drain pump
    F12 No communication between display board and
    control board
    F18 Faulty communication between microprocessor
    and DSP (Digital Signal Processor)

    #395994
    clockworkone
    Participant

    Re: h/pt bs1400

    Thank you Jim

Viewing 3 posts - 1 through 3 (of 3 total)
  • You must be logged in to reply to this topic.