2.0 uf starting Capacitor

Home Forums Public Support Forums General Enquiries And Questions 2.0 uf starting Capacitor

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #76119
    admin
    Keymaster

    Guys. (long story)

    I replaced a blower motor in an inflatable spa about 6 weeks ago. I couldn’t find the exact model as it’s a cheap chinese thing, but i did find a blower motor very similar. Incidentally its a 125mm vacuum cleaner motor.

    Yesterday I’d had the top off the pump housing to resolve a small air leak on the blower, which was causing a whislte.
    Every thing reassembled OK, and was put back in to service.

    A very short run on the blower to test functionality, with then only the water pump and heater running. About 2 hours later smoke started billowing out of the pump housing.

    I’ve stripped it this morning to find the 2.0 uf starting capacitor burnt out. I initially wondered if i’d nicked something on reassembly causing a short, but cannot see anything.

    I’m confused why the cap would burn out when the blower motor wasn’t even running, and why after a few hours post reassembly.
    The blower starts and appears to run fine with the cap removed.
    I’m considering not replacing the cap at this point.

    Any thoughts

    #397321
    admin
    Keymaster

    Re: 2.0 uf starting Capacitor

    Hi

    I would check electrically fully before using it.If it passes then everything should be fine.

    The blower motor failed on mine several years ago and I replaced the motor with a numatic one (£45) or £250 for original one guess which one i fitted.
    It’s been running fine ever since and has lasted longer than the original one..If it’s working then let it run.

    Bryan

    #397322
    admin
    Keymaster

    Re: 2.0 uf starting Capacitor

    I may have found the reason the cap blew out.
    I’ve just pulled the motor again and found that it has a small cap attached to it.
    However, foolishly, I don’t remember if the failed blower had a cap. Considering there was one on the control pcb, i’d assume that the original motor didn’t have one.
    Would having 2 caps cause one to blow ?

Viewing 3 posts - 1 through 3 (of 3 total)
  • You must be logged in to reply to this topic.