    Hi All,

    I have this fault currently (Error Code Eb). I’ve checked and the motor is cycling continuously. I’ve replaced the Triac on the PCB that I think is the Baffle motor one (it was looking a little “hot” on the PCB) but this has made no difference. Can anyone say for sure which Triac controls the motor, or suggest what else it could be?

    Thanks in advance.

    #398846
    feefifofum
    Participant

    Re: Hotpoint FF92 – Fridge Baffle Motor Running Continuously

    On the Procond-manufactured control PCB the baffle motor is connected to pins 3 and 4 of the 4-way edge connector half-way along the front edge of the PCB. The baffle switch is connected to pin 3 with its return goes via the lamp (in series) to pin 1.