    jamesbfd
    Participant

    hi all,
    i have a hoover dyn8164d L1-80 developed a problem get error code E03, so checked pump working fine pumping water out filter clean.
    i also got advised to check the water level pipe so took it off cleaned it and refitted it.
    still getting the same error code even though it is draining fine.
    i can get hold of a new pcb board but Im unsure which one i need as apparently there are three!!!
    can anyone advise which one i need or maybe something i haven’t already tried, many thanks

    #399564
    Martin
    Participant

    Re: hoover dyn8164d L1-80

    Check for poor heater insulation as that will throw up a random E03 error code. 😉

    #399565
    jamesbfd
    Participant

    Re: hoover dyn8164d L1-80

    thanks for replying martin!
    i probably sound like a bit of a div but how do u do that???

    #399566
    Martin
    Participant

    Re: hoover dyn8164d L1-80

    With a 500dcV insulation tester ( often referred to as a Megger). If the insulation is that bad on the heater then a regular 9volt multimeter will show it anyway. But likely as not low insulation will only show using a Megger. Anything lower than 40 megohms will give an E03 error.

    #399567
    jamesbfd
    Participant

    Re: hoover dyn8164d L1-80

    Hi martin had I tested an its showing 50, what now

    #399568
    Martin
    Participant

    Re: hoover dyn8164d L1-80

    Replace it.

    #399569
    jamesbfd
    Participant

    Re: hoover dyn8164d L1-80

    I replaced it and im still getting the same code!!!
    seriously loosing the will to live with this machine, any suggestions

    #399570
    Martin
    Participant

    Re: hoover dyn8164d L1-80

    Have you taken the pump/filter unit right off? Often coins (2p usually) can get stuck in the inlet (sump) hose and act like a valve. Well worth double checking.

    #399571
    jamesbfd
    Participant

    Re: hoover dyn8164d L1-80

    yeh i took the pump off all the hoses and gave them a good scrub for good measure

Viewing 9 posts - 1 through 9 (of 9 total)