hoover pe235 tripping Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › hoover pe235 tripping This topic has 3 replies, 3 voices, and was last updated 12 years, 7 months ago by clockworkone. Viewing 4 posts - 1 through 4 (of 4 total) Author Posts August 19, 2013 at 2:07 pm #76750 clockworkoneParticipant this m/c keeps on tripping breaker. heater is checking out fine insulation etc.motor the same.any ideas. August 19, 2013 at 2:41 pm #399658 nigegtParticipant Re: hoover pe235 tripping Faulty mains suppressor could be the issue. Nige August 19, 2013 at 6:55 pm #399659 clockworkoneParticipant Re: hoover pe235 tripping Thanks Nige. suppressor looks ok.Was thinking poss timer motor asit seems to happen at roughly same time in on cycle just like you would expect off heater. August 20, 2013 at 10:28 pm #399660 MartinParticipant Re: hoover pe235 tripping A Megger test would show up all components with earth issues so I reckon it is a wiring harness problem. When she shakes she breaks!” Author Posts Viewing 4 posts - 1 through 4 (of 4 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In