Belling F/F BK66CRM

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #77504
    conormccleane
    Participant

    Hi,
    No cooling in fridge or freezer. Lights on but no compressor action. Doesn’t appear to have a conventional thermostat (visible). Customer reports power cuts day or two before fault noticed. Just wondering is the electronic the problem?

    Anyone have a problem with these before or what should I check on pcb?

    Muchos grassyarse,
    C.

    #402395
    Hollytree_Technical
    Participant

    Re: Belling F/F BK66CRM

    Assuming that the compressor is OK and the light is not controlled by the PCB then the first thing I would check/replace would be the X2 class capacitor (Large grey block labelled C1 in your photo). If the capacitor is OK then I would check whether or not you can get any continuity through the large pink fusible resistor (R3 – looks like 41 Ohms but not sure).

    Jem

    #402396
    conormccleane
    Participant

    Re: Belling F/F BK66CRM

    Thanks Jem,
    Cap C1 & R3 measuring OK.
    C.

    #402397
    conormccleane
    Participant

    Re: Belling F/F BK66CRM

    Any other suggestions? 🙂

    #402398
    conormccleane
    Participant

    Re: Belling F/F BK66CRM

    TC2, TC3, & C3 ok also. TC1 on other side has no middle leg – looks intentional though. What are DU1 and DU2? Is VR1 a cap? (purple? thingy), 11 o clock to P1.
    C.

    #402399
    Hollytree_Technical
    Participant

    Re: Belling F/F BK66CRM

    Not sure what DU1 and DU2 are but from this angle they might be diode pairs, VR1 looks like a Voltage Dependant Resistor (Surge Protection). Might need some better photos (different angles and other side) to be sure.

    #402400
    conormccleane
    Participant

    Re: Belling F/F BK66CRM

    Thanks again Jem,
    Will try to photo and post.
    C.

Viewing 7 posts - 1 through 7 (of 7 total)