Re: BEKO WM 5140 S Tripping RCD
You can do tests on bench, test from motor pins to frame, you don’t want anything lower than 3meg i’d imagine & as high as possible. Heater & motor would be the components that you would mostly have an earth fault on causing tripping.
Best to start testing at plug first, check lead/plug with it disconnected from filter/interference suppressor, go through appliance from there, checking each component:-
pump, heater, motor, filter, loom, valves etc..