Bosch WTL6103GB/01 pump runs for 30sec @ start, then nothing

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Bosch WTL6103GB/01 pump runs for 30sec @ start, then nothing

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #77795

    Checked on timed as well as auto dry programmes. Always the same. I did smell the heater coming on at one point but never saw the drum move. Drum / belt / motor moves freely by hand. Capacitor reading 8uF. Condenser clean and housing etc. behind all that seems clear.
    Apparently hasn’t worked for about a year (since being moved from another address where it was working) and has been in reasonably dry shed all that time. I took side panels off but couldn’t figure how to get pump out or anything much really. Too dark and dismal to spend much time in that shed so came away to get more info.
    Not urgent, but if anyone has any ideas other than “change board” I’d be happy to hear them. 🙂 .
    Mike.

    #403423
    Martin
    Participant

    Re: Bosch WTL6103GB/01 pump runs for 30sec @ start, then not

    Corroded motor plug connector block I would think Mike. Motor slides out of the back having first removed the heater/fan housing backplate, undone the front fan and unscrewed the drive shaft coupling.

    #403424

    Re: Bosch WTL6103GB/01 pump runs for 30sec @ start, then not

    Thanks Martin; I’ll let you know in due course if you’ve won 😉 .