Miele T230C Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Miele T230C This topic has 2 replies, 2 voices, and was last updated 12 years, 4 months ago by timdowning. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts December 10, 2013 at 4:53 pm #78545 timdowningParticipant The stat on the heater assy is open circuit. Its rated at 160 oC. Does anyone know if this is a one shot or normal operating? I couldn’t see another stat anywhere and the only other part on the heater is a ntc probe. Thanks. December 10, 2013 at 5:52 pm #406056 SeamyParticipant Re: Miele T230C As far as I can see theres a “temperature limiter” & NTC listed for it, so presume its a one shot device. You want to check why its gone though before fitting another. Look for blockage in duct, problem with fan, relay fault etc. December 10, 2013 at 7:05 pm #406057 timdowningParticipant Re: Miele T230C Thanks for quick reply. So is heater switching (on & off) done by just the reading from the NTC to control card? Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In