  • #78545
    timdowning
    Participant

    The stat on the heater assy is open circuit. Its rated at 160 oC.

    Does anyone know if this is a one shot or normal operating?
    I couldn’t see another stat anywhere and the only other part on the heater is a ntc probe.

    Thanks.

    #406056
    Seamy
    Participant

    Re: Miele T230C

    As far as I can see theres a “temperature limiter” & NTC listed for it, so presume its a one shot device. You want to check why its gone though before fitting another.
    Look for blockage in duct, problem with fan, relay fault etc.

    #406057
    timdowning
    Participant

    Re: Miele T230C

    Thanks for quick reply.
    So is heater switching (on & off) done by just the reading from the NTC to control card?