Hotpoint FDW80 no heat

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #78571
    Washdisher
    Participant

    Hi folks,

    Continuity across heater but leads to heater read about 20 volts less than mains

    Wiring appears to be ok and no damage at hinge area.

    Pressure switch switches and doesn’t have high resistance.

    No obvious damage to board but I’m thinking heater relay?

    Any help gratefully received.

    #406129
    Washdisher
    Participant

    Re: Hotpoint FDW80 no heat

    Sorry, forgot to mention error code which is AL08 for what it’s worth

    #406130
    A1engineer
    Participant

    Re: Hotpoint FDW80 no heat

    yeah 100bit timers on these are very prone to no heat faults

    Al08 just means time out heating

    #406131
    Washdisher
    Participant

    Re: Hotpoint FDW80 no heat

    Thanks A1

Viewing 4 posts - 1 through 4 (of 4 total)
  • You must be logged in to reply to this topic.