Smeg D/W 1+5 steady?

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #78899
    iadom
    Moderator

    DI612CA, customer on phone says that it will not start and on opening lights 1+5 are on steady. This does not appear to be a proper error code. I have asked him to check if it is 1 flashing and 5 steady but he is at work ATM so won’t know until later.

    Is 1+5 lights on steady a known code?

    Jim.

    #407316
    smeghead
    Participant

    Re: Smeg D/W 1+5 steady?

    never heard of it, they must mean E1 error, ( 1. flashing , 5. Constant ) leak /aquastop

    Clive

    #407317
    iadom
    Moderator

    Re: Smeg D/W 1+5 steady?

    That was what I also suspected, told him to drag it out and tilt it.

    He phoned back to say that water ran out and it is now working fine. I have some small O rings on order for when he calls back to say it’s stopped again. 😉

    #407318
    smeghead
    Participant

    Re: Smeg D/W 1+5 steady?

    he will be back!!