AEG dishwasher pnc 91193861013 i60 fault Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › AEG dishwasher pnc 91193861013 i60 fault This topic has 1 reply, 1 voice, and was last updated 12 years ago by allan73. Viewing 2 posts - 1 through 2 (of 2 total) Author Posts March 19, 2014 at 12:38 pm #80007 allan73Participant I’ve got the above with an i60 fault code and lots of steam coming out. Does anyone know which terminals on the board are for heater continuity ? Allan March 20, 2014 at 12:00 pm #411322 allan73Participant Re: AEG dishwasher pnc 91193861013 i60 fault Been out to this today. No visual signs of a problem on the board, water sits just under an inch above the filter and heater still works. Where would the NTC be located on this ? Allan Author Posts Viewing 2 posts - 1 through 2 (of 2 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In