  • #80173
    pmb
    Participant

    Zanussi ZWD16270w1 Washer Dryer
    Three weeks ago found wire adrift from dryer temperature probe on lower hose was OK for a couple weeks
    But now dryer time too quick and it also goes to zero before its finished when I put on test fault code E73 Comes up,(dryer NTC) put new Thermister probe in but still the same.
    Anyone got any ideas

    #411978
    Martin
    Participant

    Re: Zanussi W/D Dryer time shortened

    Which NTC did you replace?

    #411979
    pmb
    Participant

    Re: Zanussi W/D Dryer time shortened

    The one in the lower hose from condenser to tub

    #411980
    Martin
    Participant

    Re: Zanussi W/D Dryer time shortened

    E73 refers to the dryer NTC in the heater duct, hence why I asked the question:wink:

    #411981
    pmb
    Participant

    Re: Zanussi W/D Dryer time shortened

    I assumed NTC would be torpedo type, Three on heater duct all look like thermostate s
    So is it the one in the front

    #411982
    Martin
    Participant

    Re: Zanussi W/D Dryer time shortened

    pmb wrote:So is it the one in the front

    Yes!

    #411983
    pmb
    Participant

    Re: Zanussi W/D Dryer time shortened

    Thanks Martin its all ok now,