ParticipantHi Folks,
Hoover DST10146P , it does the first water fill on drawer 1 ok then switches to compartment 2 in the soap drawer,.. and just keeps filling !!!!
I’ve had all the pipes off to check there are no blockages and can hear the pressure switch click when I blow into the small tube that connects to it.
Can anyone help ?
Donna x
May 24, 2014 at 9:02 pm #414354Martin
ParticipantRe: Hoover DST10146P overfilling
Air leak in hose to pressure switch?
May 24, 2014 at 9:09 pm #414355chucklebutty
ParticipantRe: Hoover DST10146P overfilling
I had thought that, but then it does the first prewash fill ok then just keeps going on the second one. ?
If it was an air leak,. wouldn’t it just keep filling on the first one ?
May 24, 2014 at 9:29 pm #414356Martin
ParticipantRe: Hoover DST10146P overfilling
chucklebutty wrote:If it was an air leak,. wouldn’t it just keep filling on the first one ?
True.
The air chamber attached to the tub is a caution and prone to getting gunged up. Difficult to access too. Not error codes show on the display I suppose?
May 24, 2014 at 9:50 pm #414357chucklebutty
ParticipantRe: Hoover DST10146P overfilling
E02 sometimes., others,. it just keeps filling the drum ?
May 24, 2014 at 10:02 pm #414358iadom
ModeratorRe: Hoover DST10146P overfilling
Initial fill could also be timed as opposed to pressure switch controlled.
May 25, 2014 at 7:00 am #414359Martin
ParticipantRe: Hoover DST10146P overfilling
chucklebutty wrote:E02 sometimes., others,. it just keeps filling the drum ?
Well E02 is a fill error anyway. You let me know what “others” show up, meanwhile check out that air chamber attached to the tub.
May 25, 2014 at 8:23 am #414360chucklebutty
ParticipantRe: Hoover DST10146P overfilling
I traced the tube from the pressure switch to find the chamber, but it goes straight into the drum ! Our old one had a bottle thing on the side !
Does this model have it inside the drum ? or is it straight to the pressure switch ?
May 25, 2014 at 8:42 am #414361Martin
ParticipantRe: Hoover DST10146P overfilling
chucklebutty wrote:Does this model have it inside the drum ?
Yes it’s a chamber moulded into the drum. I use a large syringe to flush it out.
May 28, 2014 at 7:19 pm #414362chucklebutty
ParticipantRe: Hoover DST10146P overfilling
Flushed it.,, a little resistance to start with but fine.
Started the washing machine again,. and same thing.,, does the first little fill of water into drawer (1) stops., then goes onto fill from drawer (2) and just keep going,.. and going,., and going ! I had to stop it myself as it was 3/4 way up the glass.
So…, now what ?
May 28, 2014 at 7:28 pm #414363Martin
ParticipantRe: Hoover DST10146P overfilling
Replace the pressure switch and double (treble) check the air hose is not punctured. It is one or the other.
June 2, 2014 at 6:47 pm #414364chucklebutty
ParticipantRe: Hoover DST10146P overfilling
Pressure switch changed., hose checked.,, and STIIL THE SAME 🙁
Doing the first fill of water.,, stopping then going onto the second fill and just keeping going until error E02 shows !
June 2, 2014 at 8:08 pm #414365Martin
ParticipantRe: Hoover DST10146P overfilling
Hmmmm…? I wonder if the inlet valve triac on the circuit board has blown? Clutching at straws now on this. 🙁
June 4, 2014 at 7:07 pm #414366gergswin
ParticipantRe: Hoover DST10146P overfilling
Try clipping of the ends of the pressure pipe, about 1cm at each end then connect back with the spring clips,The pipe will then fit tight.
let me know how you go on. -