Bosch HBC84E653B inverter mwave resetting after 8 secs

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Bosch HBC84E653B inverter mwave resetting after 8 secs

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #80883
    Washdisher
    Participant

    and not heating. Suspect main control board or inverter.

    Mag ok as far as I can tell.

    During the eight seconds it runs there is:

    Mains voltage to inverter input

    4.69 V DC between brwn/white and blue/white, and between 0.1 and 0.7 V DC between brown and blue of inverter control terminal.

    On Panasonic models I believe there should be about 3v AC between brown and blue of inverter control signal. Anyone have any info on testing these I’d be v grateful.

    Dez

    #414734
    electrofix
    Moderator

    Re: Bosch HBC84E653B inverter mwave resetting after 8 secs

    all that’s happening is the mag is not starting.
    on these units if the invertor does not detect mag start it shuts it down

    its going to be the mag or invertor. I would swop the mag first and see what happens

    cheapest place I found for invertors so far is ebay. user in Scotland

    Dave

    Dave

    #414735
    Washdisher
    Participant

    Re: Bosch HBC84E653B inverter mwave resetting after 8 secs

    Hi Dave,

    You were absolutely right – the mag was burned out. All sorted now. Thanks for nudging me in the right direction and for the Ebay info.

    Dez

Viewing 3 posts - 1 through 3 (of 3 total)