    Washdisher
    Participant

    Visited about 6 months ago to attend to clothes not drying.

    TOC had tripped. Machine looked very clean and new, so reset TOC and went on my way.

    Tripped again a few weeks later.

    Went back and replaced thermistor. Apparently the heater is now switching off before clothes are dry (TOC not tripping). It’s as if both the original and replacement thermistors were out of spec, but in different directions (if that makes sense).

    I read an other post on a similar issue with this machine, where replacing the entire duct and fan assy was suggested. Seems a bit drastic but I’m open to ideas.

    Cheers, Dez

    #415382
    Martin114
    Participant

    Re: Samsung WD8704RJA

    Sounds like a blocked steam condenser?


    Sent from my iPad using Tapatalk HD

    #415383
    admin
    Keymaster

    Re: Samsung WD8704RJA

    in the past I’ve had to clean some fluff from the fan blades they have been blocked up, once this was done all was good, and never missed behaved
    canufixit

    #415384
    Lawrence
    Participant

    Re: Samsung WD8704RJA

    Assy duct scroll

    DC9300033A
    clean the condenser as well

    #415385
    Washdisher
    Participant

    Re: Samsung WD8704RJA

    Thanks for all your help Mertin114, Canufixit and Lawrence. I’ll go back and strip it down.