Home › Forums › Public Support Forums › Help And Support › Cooker And Oven Forum › Hotpoint HUD61X Grill fan stays on constantly
- This topic has 6 replies, 4 voices, and was last updated 11 years, 9 months ago by
garry247.
-
AuthorPosts
-
July 11, 2014 at 11:04 am #81423
garry247
ParticipantThe Grill fan keeps blowing out cold air. Even when the grill is off. It has been doing this constantly for two days now.
Is it something i need to clean or a faulty switch?
The cooker is 3 years old and is a dual fuel double oven. The top oven is also the grill.Cheers,
Garry
July 11, 2014 at 11:28 am #416545Martin
ParticipantRe: Hotpoint HUD61X Grill fan stays on constantly
The thermal cut out that operates the cooling fan needs replacing by the sound of it.
July 11, 2014 at 1:18 pm #416546garry247
ParticipantRe: Hotpoint HUD61X Grill fan stays on constantly
Thanks for the quick response,
I was looking at this part: http://www.partmaster.co.uk/hotpoint/hu … ref=924133
I have seen a video on how to get the top off an electric cooker:
http://www.youtube.com/watch?v=JYln4FzJPdkMy cooker is Dual Fuel.
I have 2 questions
1. Where would i find this thermostat and if its under the top is is hard to get at on a Gas top?
Thanks again,
Garry
July 11, 2014 at 2:47 pm #416547Martin
ParticipantHotpoint HUD61X Grill fan stays on constantly
Garry the TOC is located near the cooling fan, as your pic shows. I’m not Gas Safe registered so I don’t touch gas appliances. But at least you’ve have more than enough info now to get stuck in, should you take the DIY route.
July 11, 2014 at 3:07 pm #416548garry247
ParticipantRe: Hotpoint HUD61X Grill fan stays on constantly
Thanks everyone for all your help.
😀
G.
May 9, 2016 at 3:58 pm #416549DaveA68
ParticipantRe: Hotpoint HUD61X Grill fan stays on constantly
Garry
Did it work and was it easy? My HUD61 is doing the same and is only 2 years old. What termostat do I change and where can I get it from cheers
June 18, 2016 at 10:27 am #416550hardyd44
ParticipantRe: Hotpoint HUD61X Grill fan stays on constantly
hi, I have the same problem with my hud 61x, however the Thermal cut in is fine, I have disconnected it and the fan still kept running, took it out of the cooker and tested with a multi meter and heat source – switch in and out as it should. I have disconnected the other feed from the grill control switch and the fan has stopped – so I assume the switch is now faulty but cannot identify the correct replacement switch/control (lots of similar looking ones varying in price from £10 to £60) – can anyone identify the correct part for me?
-
AuthorPosts
- You must be logged in to reply to this topic.