    Hi folks,

    I’ve now been through nearly 300 separate posts,videos and “how-to’s” on how to fix this damn fridge, and nothing seems to work!
    The problem started last week, with the fridge and freezer no longer cooling. A few hours later the fridge started making a buzzing noise when the door was closed. The compressor was also very hot to the touch.
    Now, since then, I have had the compressor coils checked, and they are fine (19.9 ohms/32.7 ohms/13.8 ohms). Also, current is being sent to the compressor, but it “clicks” and does nothing (safety mode?!). I have since changed the PCB, and connected up a “same-version” brand new compressor and dry tested it. It did not run (despite there being current supplied!). And the board still buzzed. I have now removed the internal fridge fan (which causes this buzzing when the door is closed), and it is giving no resistance reading at all, so I assume it is dead? (I was hoping to bench test it, if someone could tell me which wires to shunt – I think its black and yellow together +ve, and then grey -ve?)
    No error code when running the self-diagnostic mode (did have a Coolzone sensor error, but only when the Coolzone tray was disconnected and removed).
    So would the fridge fan being dead cause the compressor not to run?
    I have tried to a forced pull-down (test-mode, then one press of any button) but the compressor did not start.
    Please, please, please, can someone tell me how to fix this?
    P.S. I WOULD love to get an engineer to sort it, but unfortunately I live in the middle of rural France, and no engineer will come out!!
    Thanks in advance! 🙂

    #417080
    Barry1979
    Participant

    Re: Samsung RS55XKGNS problems – (same internals as RS21)

    Oh, and I have checked the temperature sensor, it’s working correctly. And the thermal fuse, which is also functioning correctly. 👿

    #417081
    admin
    Keymaster

    Re: Samsung RS55XKGNS problems – (same internals as RS21)

    Hi Barry

    Have you tested the defrost heater ? also remember that you must disconnect the drain heater else you will get false readings

    Bryan

    #417082
    Barry1979
    Participant

    Re: Samsung RS55XKGNS problems – (same internals as RS21)

    Thanks for getting back to me Brian.

    I can’t test the defrost heater, as, having seen it should give a reading of approx 485 ohms if working correctly, my Fluke 7-600 only reads up to a max of 400 ohms! Doh!!
    And my 1652C got nicked at a job last frikkin’ week! 👿
    Any workarounds?
    And would this stop the compressor from running (also, wouldn’t there be an error showing up?)

    Thanks!

    #417083
    admin
    Keymaster

    Re: Samsung RS55XKGNS problems – (same internals as RS21)

    e mail me samsung@ffrservices.co.uk

    Bryan

    #417084
    Barry1979
    Participant

    Re: Samsung RS55XKGNS problems – (same internals as RS21)

    New fan fitted, still no joy…………………………….. GRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRR!!!