  • #81589
    mjhservices
    Participant

    Hotpoint WMUD942

    Just pumps all the time although its not the pressure switch and there’s no water inside?

    Also is there a test cycle for these new Hotpoint machines?

    Regards Mark

    #417105
    electrofix
    Moderator

    Re: Hotpoint WMUD942

    does it pump the minute you plug in ?

    the minute you turn it on ?
    when you set a prog and start it ?

    or a couple of seconds or minutes after you start it ?

    first thing i would check for
    1 anything that looks like a fault code
    2 earth faults in the pump circuit( dont get as much these days as it blows rcd but there are still properties without them )
    3 shorted pump triac on pcb

    Dave

    #417106
    johnnyj
    Participant

    Re: Hotpoint WMUD942

    Had one today put a new linear pressure switch in worked a treat.