diplomat ADP8502 854500115710 flashing 2 times now 6 times

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries diplomat ADP8502 854500115710 flashing 2 times now 6 times

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #82010
    alro
    Participant

    Hi gents have adp8502 flashing 2 times checked flow meter as water goes in but no wash action tightened connectors got wash action for seconds and dispensor door opened stopped filled a bit then stopped and now flashing 6 time any ideas please
    cheers alro

    #418410
    electrofix
    Moderator

    Re: diplomat ADP8502 854500115710 flashing 2 times now 6 tim

    as you prob know they are 2 unrelated faults

    F2 is flooded base

    F6 is tap turned off

    its not unusual for the flow meters to go faulty ( i solder in new reed switches ) also these units are prone to breaking the wires in the door

    Dave

Viewing 2 posts - 1 through 2 (of 2 total)
  • You must be logged in to reply to this topic.