    Morning All,

    last week our washing machine caused a mcb to trip out, when I sorted that out it was displaying E01, which according to the error code help suggests that there is a problem with the door interlock.

    So I replaced that module but it still displayed E01, investigating further one of the fuse tracks on the controller PCB had blown. So I’ve replaced that this morning but on doing a test (did drain program first, then a rinse and spin) then same fuse track has blown again, along with the other one.

    Any suggestions

    Cheers

    Steve

    #418750
    nigegt
    Participant

    Re: Hoover DYN8164D Controller Board

    Sounds like a motor fault. When it blows the board to bits it shows a door lock error just to keep you guessing! Had it on many occasions. Check the rectifier pcb also as it tends to affect that too.

    Nige

    #418751
    sfozz
    Participant

    Re: Hoover DYN8164D Controller Board

    Hi Nige,

    is the rectifier PCB mounted on the motor? Apart from the controller I’ve only seen the RF suppression cap.

    Cheers

    Steve

    #418752
    sfozz
    Participant

    Re: Hoover DYN8164D Controller Board

    Hi Nige,

    OK the rectifier has 3 burn out tracks, I can’t see any scorching on the motor.

    So is the root cause here the rectifier, or would something else have drawn too much current to burn out the rectifier?

    Cheers

    Steve

    #418753
    nigegt
    Participant

    Re: Hoover DYN8164D Controller Board

    Yes the motor fault draws too much current and blows the rectifier.