    This indesit w/m will not shut down at end of cycle.Cust has to switch off at socket.They say it does everything it should bar switch off.

    #420513
    aqualectric
    Participant

    Re: wia101

    Heater short or PCB.

    HTH,

    Steve.

    #420514
    aqualectric
    Participant

    Re: wia101

    Heater open circuit, short or PCB.

    HTH,

    Steve.

    #420515
    clockworkone
    Participant

    Re: wia101

    Thank you aqualectric.