    SpeedyFix
    Participant

    Hi can anyone tell me E30 fault on an Zanussi ZWG1120Pwashing machine. Have replaced a pressure switch but still no joy. Inlet solenoids check out both eclectically and mechanically, but don’t engage in the cycle to let water in. Thanks

    #420774
    Seamy
    Participant

    Re: Re:Zanussi ZWG1120P

    E30 on a ZWG1120P refers to pressure system fault, E30 on a ZWG1120M refers to door lock fault.

    #420775
    SpeedyFix
    Participant

    Re: Re:Zanussi ZWG1120P

    Hi Seamy
    thanks for the reply, I have replaced the pressure switch, door lock is
    operating perfectly. Just to clarify it is 1120P. When I switch it on the door lock locks, after may be 20seconds the e30 fault shows but the
    inlet solenoids don’t come in and fill the machine. I have tested solenoids electrically and mechanically, they work perfectly.has me stumped as Ive checked everything and cannot find a problem. Any further advice or insight would be appreciated.

    #420776
    Seamy
    Participant

    Re: Re:Zanussi ZWG1120P

    Does pump run after door locks and programme starts? It should so start by checking there.