Samsung RS21DGRS Tripping

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #83023
    jag-12
    Participant

    Having a problem with this unit in that it blows the trip after running normally for 2-3 days
    Leave it of for a day and starts up again fine then after 2-3 days it blows trip again.
    Have meggered eveything I can think off and all checks out fine.
    Water is not connected and ice turned of at control panel.
    Suspect defrost water might be getting somewhere it shouldnt but cant catch it out

    Any clues as to where I should be looking?

    #421485
    SAMURI
    Participant

    Re: Samsung RS21DGRS Tripping

    Most likely the defrost heater in the fridge faulty

    This is the most common fault for intermitatantly tripping the RCD

    Bob

    #421486
    funkyboogy
    Participant

    Re: Samsung RS21DGRS Tripping

    yip 99.9{e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d} it will be fridge defo ele

    you can unplugg and let the unit run for a few day just to confirm it is the element

    need to remove bottom fan cover to access the plugs , defo element is the middle plug .

    need to take of top light cover to get bottom cover of easy enough job

    ally.