Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Miele W806 pressure system location?
- This topic has 5 replies, 3 voices, and was last updated 11 years, 4 months ago by
Gertrude.
-
AuthorPosts
-
December 1, 2014 at 2:16 pm #83242
Gertrude
ParticipantHi,
Been out of the game for a while but still occasionally get the tools out for the usual friends and family jaunts.
My machine this time!
A very reliable Miele W806.
Machine over filling and/or not spinning and door not opening.
If turned off and left for a while it would seem pressure eases and will then move on.Silly question I know but where is the pressure chamber?
Lack of space in the flat has me hoping it’s via the front panel.Any advice greatly appreciated.
Many thanks.
Regards,
Gary
December 1, 2014 at 2:21 pm #422172eastlmark
ModeratorRe: Miele W806 pressure system location?
front off, just next to the heater. Beware though the dreaded underfill fault after cleaning which needs re setting by a Miele man with laptop…. hopefully you will be alright but would suggest testing the heater while you are in there.
December 2, 2014 at 11:58 am #422173Gertrude
ParticipantRe: Miele W806 pressure system location?
Thanks eastlmark.
Not familiar with the “dreaded underfill fault” (or much else nowadays!). Would you kindly elaborate, please?
Chamber was blocked so cleared and all appears okay now e.g. water came in to a reasonable ‘below drum rim’ level, heated, drum action and drained. Better half trying full wash tonight.
(Heater 22ohms. Didn’t test sensor :oops:)Many thanks for the advice. 😀
December 2, 2014 at 1:45 pm #422174clayside
ParticipantRe: Miele W806 pressure system location?
Sounds like you should be ok. On this model sometimes after the blocked chamber has been cleaned it can cause the machine to under fill causing heater failure. 22ohms is about right for heater.
December 2, 2014 at 11:25 pm #422175eastlmark
ModeratorRe: Miele W806 pressure system location?
yes, heater is fine then, would have been open circuit if faulty due to the pressure chamber being blocked.
December 4, 2014 at 2:03 pm #422176Gertrude
ParticipantRe: Miele W806 pressure system location?
The machine appears to be working fine now :tup:
Might do dampers and brushes next year :study:
Many thanks for the advice chaps.
Much appreciated.
-
AuthorPosts
- You must be logged in to reply to this topic.