Zan W/D – Dryer timer Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Zan W/D – Dryer timer This topic has 2 replies, 2 voices, and was last updated 11 years, 3 months ago by DDDave. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts December 20, 2014 at 1:46 pm #83475 DDDaveParticipant Hi, We have a Zan W/D ZWD1471W 914601126/00. The error code E73 is coming up. We replaced the NTC in the condenser duct. The dryer timer is counting down incorrectly. For every 12 seconds it is moving on 1 minute. Can anyone help? December 20, 2014 at 8:36 pm #422848 MartinParticipant Re: Zan W/D – Dryer timer Break in the wiring to the NTC in the condenser bottom hose or earth leak to element are 2 possibilities? December 21, 2014 at 11:01 am #422849 DDDaveParticipant Re: Zan W/D – Dryer timer Thanks Martin. I put new spades on the NTC about a year ago and have tested the element for earth leaks. Any other possibilities please ?? Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In