Sandstrom SFF4DS11

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #84060
    Lawrence
    Participant

    anyone got experience of these
    fault is the freezer has stopped working ,fan blows but no cold air at all ,fridge works perfectly however

    #424643
    SAMURI
    Participant

    Re: Sandstrom SFF4DS11

    I have never worked on this make but looking at the diagram I would say check the rear of the appliance to see if the external fan is working and the condenser is clear off fluff.

    If the fan and condesor is clear. then You can then check to see if the compressor is running hot / low on gas or compressor fault.

    If there is some cooling in the freezer then I would check it has defrosted itself correctly and the internal fan is working before breaking into the system.

    Hope this helps see you next week.

    Bob

    #424644
    Chris Blatch
    Participant

    Re: Sandstrom SFF4DS11

    I know they are a dual evaporator, so there is a diverter valve, allowing vacation mode etc.

    #424645
    Steven
    Participant

    Re: Sandstrom SFF4DS11

    Hi Guys, I have been out to one of these, blowing fuses. I checked the relay and it smells burnt out! I can’t locate a relay it states only compressor.
    As I don’t know if there is anything else wrong I don’t want to spend over £140 on a pot that i can’t use for the sake of a relay.
    Is there any other start device that would work on this unit?

    Cheers
    Steven

    #424646
    SAMURI
    Participant

    Re: Sandstrom SFF4DS11

    A FRG9343 from Connect may fit and are only about £3 inc vat
    It will fit most compressors as long as there is room for it.

    Bob

Viewing 5 posts - 1 through 5 (of 5 total)
  • You must be logged in to reply to this topic.