Beko Tumble Dryer DCU9330W

Home Forums Public Support Forums Help And Support Tumble Dryer Help Forum Beko Tumble Dryer DCU9330W

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #84609
    admin
    Keymaster

    Hi,

    I have the following Beko Tumble Dryer DCU9330W and its 3 years old as of late I have noticed that I have to run it three times for the cloths to completely dry at the end of the cycle the clothes are not completely dry and need more drying time. I have cleaned the filter, condenser and sensors, but the problem still happens. this is on the extra dry setting at the highest drying level.

    Although the appliance does appear to be heating up fully its just not drying correctly on the first cycle.


    Can anyone advise what I can do to resolve this? Or would it be best to look for a new tumble dryer?

    #426252
    admin
    Keymaster

    Re: Beko Tumble Dryer DCU9330W

    Just wondering if someone could please shed any light on how I can try and resolve this issue? I was wondering if it would make any difference to have the dryer venting outside by a hose instead of using the water tank?

    #426253
    Seamy
    Participant

    Re: Beko Tumble Dryer DCU9330W

    Tip appliance up, look underneath to rear, there’s a short 3-4 inch long ribbed grey pipe, take it off & clear it out, it normally blocks with fluff, which can cause problems with water drainage to tank.
    Other problems with this model is heater going low to earth, if this is so, heater element needs changed.